<LOGO>
FM Transmitter Measurement Report
Created: 2024-11-26 13-15-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.70 MHz 4/5, 27 dBuV INFO
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 51 kHz 6187 0,0808
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
3,0 dBr 4,13 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INFO " F206 0 (No PTY) 0 0 0 0 13:15, 26.11.2024
RT
"LE 12 / 15 - M. BERNARDEAU ET F. CARBONNE - FRANCEINFO "
AF EON
103.1, 105.5, 105.7 MHz F201, F207, F202
FM Scope Station: 105.70 MHz, signal: 4/5 (27 dBuV) Max at: 51 kHz MIN: 12 kHz % above 75 kHz: 0,0808 Acquired: 2024/11/26 13:14:40 Total samples: 6187 Equivalent time: 0:05:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 5,5 dBr MIN: 3,0 dBr AVE: 4,13 dBr % above 11,2 dBr: 0,0 Last value: 4,2 dBr (2024/11/26 13:14:40) Station: 105.70 MHz, signal: 4/5 (27 dBuV) 13:02 13:04 13:06 13:08 13:10 13:12 13:14 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality